The symptoms exhibited by this Trace Elliot GP12 repair were a loud hum and distortion evident during note decay. Unfortunately I wasn’t able to replicate the customer’s problem which makes repair difficult, so I took a number of steps.
I left the amp on soak test for 2 hours, which involves heavily driving the output stage – this normally shows up faults that are temperature or power supply related.
What I did find was that one of the internal IDCs was causing audible noises when manipulated. I’ve seen this before with another Trace Elliot GP12 repair Mostly crackles, although there was a slight increase in hum sometimes which matched the symptoms described. Cleaning the IDC fixed this and that connection is now stable. I also cleaned the FX loop sockets because unused FX loops are a prime candidate for noises such as those described.
As part of a general service I also cleaned the Graphic sliders as there were a few little crackles – nothing to do with the described fault.
The next step in hum busting would have been to replace the reservoir caps. I avoided this because it adds significant cost and I had no concrete reason to suspect them. The description of the distortion on the note tail does sound a bit like caps, but the soak test didn’t reveal any problems with them.
The amp was returned to the customer. When I contacted him again the next month, the amp was still working well, another successful repair!